Building Data: Owner: Eileen and Steve Benner Designer: Steven D. Benner Builder: Gordon Jensen Caldwell, Idaho Location: Boise, Idaho Climate: 5,802 degree days Climate zone 1 Ceilings: R-49 with raised heel trusses Walls: R-30, 2x6 advanced frame, R-19fiberglass batt plus1.5" polyisocyanurate sheathing Floors: Slab on grade: R-19 continuous rigid foam. Floor over crawlspace R-30 Windows: U-0.44, 1/2" double, low-E, TIM frame. Doors: Insulated fiberglass clad Ventilation: Air-to-Air heat exchanger with duct heater Heat System: Fan-forced wall heaters Air barrier: Advanced Drywall Approach Square Footage:
Effective Solar/Total Glazing: 72% Special Features:
| Floor Plans: Upper and Lower:
Building Data Gathered Through Interview: Building secondary backup heating: Electrical in wall, 500w-100w units on individual rooms with individual thermostats. Floor solar collection system: Brick tile on concrete slab. Extruded polystyrene under slab. Siding: Beveled cedar Interior: Sheetrock, caulked and sealed with a low permeability paint. .1 Air changes per hour naturally. |